Community based action for environmental change
RSS icon Email icon Home icon
  • BOB BOYCE CELL TESTS – JUNE 08

    Posted on September 29th, 2009 Ian 1 comment

    Here are some of the results of the final run that we did with the cell.

    Test10% NaOH

    Seconds

    produce 2 ltr

    Volts Amps LPM Watts Watts / Ltr
    Efficiency
    LPM p/Sq CM Current
    Density
    Temp Efficiency (Wh/L) Efficiency (mL/W/H) % to Faraday
    1 164.7 2 #DIV/0! #DIV/0! #DIV/0! 0.0089 54 #DIV/0! #DIV/0! #DIV/0!
    2 35 169.5 3 1.7143 550 320.83 0.000635 0.0133 54 5.35 187.01 43.98%
    3 34 172.7 4 3.5294 840 238.00 0.001307 0.0178 54 3.97 252.10 59.28%
    4 29 174.1 5 4.1379 1009 243.84 0.001533 0.0222 56 4.06 246.06 57.86%
    5 21 175.4 6 5.7143 1210 211.75 0.002116 0.0267 56 3.53 283.35 66.63%
    6 16 176.4 7 7.5 1467 195.60 0.002778 0.0311 56 3.26 306.75 72.13%
    7 14 177.3 8 8.5714 1594 185.97 0.003175 0.0356 56 3.10 322.64 75.87%
    8 12 178.2 9 10 1984 198.40 0.003704 0.0400 56 3.31 302.42 71.12%
     

    One response to “BOB BOYCE CELL TESTS – JUNE 08”